vti_encoding:SR|utf8-nl vti_timelastmodified:TR|21 Mar 2013 00:58:54 -0000 vti_extenderversion:SR|12.0.0.0 vti_author:SR|JRE505-BF058AD8\\JRE505 vti_modifiedby:SR|USER-AVGPHKC51E\\Administrator vti_nexttolasttimemodified:TW|10 Jun 2008 08:16:04 -0000 vti_timecreated:TR|23 May 2008 06:41:55 -0000 vti_title:SR|COMPALARM-C3 vti_thicketdir:SW|COMPALARM-C3.files vti_timelastindexed:TW|21 Mar 2013 00:58:54 -0000 vti_backlinkinfo:VX|cpxx.files/sheet001.htm cpxx.htm vti_cacheddtm:TX|21 Mar 2013 00:58:54 -0000 vti_filesize:IR|28676 vti_cachedtitle:SR|COMPALARM-C3 vti_cachedbodystyle:SR| vti_cachedlinkinfo:VX|H|COMPALARM-C3.files/filelist.xml S|images/bjtp/dbj.gif S|images/bjtp/btbj.gif S|menu.js S|images/bjtp/wzbj.gif S|images/bjtp/wzbj.gif H|cpxx.htm H|cpxx.htm H|cpxx.htm S|images/bjtp/wzbj.gif S|images/bjtp/wzbj.gif S|images/bjtp/wzbj.gif X|COMPALARM-C3.files/image001.jpg S|COMPALARM-C3.files/image002.jpg X|COMPALARM-C3.files/image003.jpg S|COMPALARM-C3.files/image004.jpg X|COMPALARM-C3.files/image005.jpg S|COMPALARM-C3.files/image006.jpg X|COMPALARM-C3.files/image007.jpg S|COMPALARM-C3.files/image008.jpg X|COMPALARM-C3.files/image009.jpg S|COMPALARM-C3.files/image010.jpg X|COMPALARM-C3.files/image011.jpg S|COMPALARM-C3.files/image012.jpg S|images/bjtp/wzbj.gif S|images/bjtp/wzbj.gif H|mailto:info@jre.com.cn H|http://www.jre.com.cn H|http://www.cnjre.cn vti_cachedsvcrellinks:VX|FHUS|COMPALARM-C3.files/filelist.xml FSUS|images/bjtp/dbj.gif FSUS|images/bjtp/btbj.gif NSUS|menu.js FSUS|images/bjtp/wzbj.gif FSUS|images/bjtp/wzbj.gif FHUS|cpxx.htm FHUS|cpxx.htm FHUS|cpxx.htm FSUS|images/bjtp/wzbj.gif FSUS|images/bjtp/wzbj.gif FSUS|images/bjtp/wzbj.gif FXUS|COMPALARM-C3.files/image001.jpg FSUS|COMPALARM-C3.files/image002.jpg FXUS|COMPALARM-C3.files/image003.jpg FSUS|COMPALARM-C3.files/image004.jpg FXUS|COMPALARM-C3.files/image005.jpg FSUS|COMPALARM-C3.files/image006.jpg FXUS|COMPALARM-C3.files/image007.jpg FSUS|COMPALARM-C3.files/image008.jpg NXUS|COMPALARM-C3.files/image009.jpg FSUS|COMPALARM-C3.files/image010.jpg FXUS|COMPALARM-C3.files/image011.jpg FSUS|COMPALARM-C3.files/image012.jpg FSUS|images/bjtp/wzbj.gif FSUS|images/bjtp/wzbj.gif NHUS|mailto:info@jre.com.cn NHHS|http://www.jre.com.cn NHHS|http://www.cnjre.cn vti_cachedneedsrewrite:BR|false vti_cachedhasbots:BR|false vti_cachedhastheme:BR|false vti_cachedhasborder:BR|false vti_metatags:VR|HTTP-EQUIV=Content-Type text/html;\\ charset=gb2312 keywords COMPALARM-C3 description \\ COMPALARM-C3\\ \\ \\ \\  \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Compact\\ alarm\\ \\ system,\\ with\\ a\\ basic\\ module\\ of\\ 12\\ sig­nals.\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Multiple\\ modules\\ coupling\\ possibility.\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Easy\\ printing\\ of\\ the\\ Alarm\\ points\\ description.\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Optoisolated\\ inputs\\ for\\ 5¸250V,\\ NO\\ or\\ NC\\ contacts,\\ which\\ can\\ be\\ set\\ point\\ by\\ point.\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Signal\\ power\\ free\\ inputs.\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ 8\\ Alarm\\ sequence\\ possibilities\\ according\\ with\\ ISA\\ S\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Easy\\ and\\ fast\\ programming\\ by\\ dipswitches.\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ ”First\\ out”\\ feature\\ for\\ recognizing\\ the\\ first\\ tripped\\ alarm\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Programmable\\ memory\\ and\\ signalling\\ mode,\\ when\\ re­turn\\ to\\ normal.\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Interconnected\\ systems\\ for\\ Alarm\\ Management,\\ distribu­ted\\ in\\ various\\ units.\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ High\\ safety\\ and\\ reliability,\\ with\\ self\\ diagnosis\\ function.\\ \\ \\ \\ \\ The\\ COMPALARM\\ C3\\ is\\ a\\ very\\ compact\\ and\\ effi\\ cient\\ alarm\\ system,\\ suitable\\ for\\ 12\\ points\\ connection,\\ with\\ NO\\ or\\ NC\\ input\\ contacts\\ and\\ LED\\ signals.\\ \\ This\\ system\\ is\\ supplied\\ in\\ a\\ DIN\\ 72x144\\ mm\\ enclosure\\ for\\ flush\\ mounting.\\ An\\ easy\\ alarm’s\\ description\\ printing,\\ easy\\ wiring\\ \\ by\\ plug-in\\ terminals\\ and\\ a\\ good\\ front\\ prtection\\ de­gree,\\ come\\ to\\ complete\\ this\\ attractive\\ alternative.\\ \\ The\\ COMPALARM\\ C3\\ is\\ being\\ manufactured,\\ in\\ such\\ a\\ way\\ to\\ be\\ capable\\ to\\ ensure\\ an\\ intrinsically\\ safe\\ reading\\ of\\ the\\ inputs.\\ The\\ particular\\ firmware\\ and\\ the\\ internal\\ wat­chdog,\\ allow\\ the\\ functionality\\ survey\\ of\\ the\\ systems,\\ in\\ or­der\\ to\\ enable\\ the\\ outputs\\ with\\ fully\\ operational\\ instruments\\ only.\\ \\ The\\ know\\ how,\\ used\\ in\\ the\\ present\\ instrument,\\ has\\ simpli­fied\\ the\\ circuits\\ up\\ to\\ a\\ maximum,\\ granting\\ a\\ high\\ reliability\\ and\\ safety\\ for\\ avoiding\\ false\\ signals.\\ It\\ has\\ also\\ enabled\\ to\\ have\\ a\\ high\\ immunity\\ degree\\ against\\ external\\ disturbance\\ and\\ signal\\ management\\ with\\ increased\\ voltage\\ capability.\\ \\ The\\ electronic\\ management\\ system\\ allows\\ to\\ program\\ the\\ alarm\\ behaviour,\\ according\\ with\\ the\\ ISA\\ S\\ 18.1standard,\\ so\\ as\\ the\\ inputs\\ and\\ outputs\\ position.\\ \\ The\\ COMPALARM\\ C3\\ has\\ 12\\ inputs\\ that\\ can\\ be\\ set\\ as\\ NO\\ or\\ NC\\ by\\ dipswitches.\\ All\\ inputs\\ are\\ optoisolated\\ and\\ can\\ be\\ supplied\\ with\\ any\\ voltage\\ between\\ 5\\ ¸250V\\ ac/dc.\\ It\\ has\\ been\\ also\\ foreseen\\ the\\ inputs\\ for\\ acknowledgement,\\ test\\ and\\ reset\\ push\\ buttons.\\ Every\\ alarm\\ and\\ push\\ button\\ inputs\\ may\\ accept\\ a\\ big\\ range\\ of\\ voltages\\ with\\ only\\ one\\ common,\\ in\\ order\\ to\\ allow\\ the\\ installation\\ of\\ the\\ system\\ in\\ parallel\\ with\\ the\\ loads\\ to\\ be\\ surveyed\\ (without\\ using\\ a\\ back\\ up\\ relay)or\\ with\\ other\\ annunciators.\\ \\ \\ \\ \\ \\ The\\ outputs\\ are\\ fitted\\ with\\ two\\ voltage\\ free\\ contacts\\ relays.\\ One\\ of\\ them\\ is\\ intended\\ for\\ the\\ acoustic\\ or\\ alarm\\ signalling\\ and\\ the\\ other\\ for\\ a\\ cumulative\\ of\\ alarms\\ (normally\\ excited\\ or\\ diexcited\\ in\\ case\\ of\\ alarm)\\ for\\ process\\ activation\\ appro­val,\\ in\\ presence\\ of\\ one\\ active\\ alarm\\ (or\\ non\\ resetted\\ yet)\\ at\\ least.\\ The\\ mentioned\\ relay\\ will\\ also\\ react\\ due\\ to\\ a\\ lack\\ of\\ power\\ supply\\ or\\ due\\ to\\ its\\ \\ internal\\ malfunction.\\ \\ \\ \\ \\ \\ With\\ the\\ wiring\\ of\\ one\\ cable\\ through\\ other\\ similar\\ devices,\\ it\\ is\\ possible\\ to\\ enlarge\\ the\\ system,\\ which\\ will\\ work\\ as\\ an\\ unic\\ system,\\ in\\ order\\ to\\ grant\\ a\\ correct\\ operation\\ of\\ the\\ various\\ alarm\\ sequences,\\ “fi\\ rst\\ out”\\ function\\ included\\ (see\\ table\\ of\\ ISA\\ sequences).\\ In\\ such\\ a\\ case,\\ the\\ outputs\\ can\\ be\\ detected\\ by\\ any\\ of\\ the\\ interconnected\\ modules.\\ Attention:\\ In\\ this\\ case,\\ the\\ push\\ buttons\\ should\\ be\\ fitted\\ with\\ so\\ many\\ separated\\ contacts\\ as\\ interconnected\\ mo­dules,\\ in\\ order\\ to\\ avoid\\ the\\ parallel\\ input\\ connection\\ of\\ different\\ modules.\\ \\ \\ \\ \\ \\ Each\\ COMPALARM\\ C3\\ module\\ accepts\\ up\\ to\\ 12\\ contacts,\\ with\\ a\\ common\\ pole,\\ either\\ open\\ or\\ closed\\ in\\ a\\ rest\\ posi­tion,\\ which\\ can\\ be\\ set\\ for\\ each\\ input\\ by\\ dipswitches,\\ placed\\ behind\\ the\\ alarms\\ description\\ panel.\\ The\\ activation,\\ memory\\ and\\ reset\\ modes\\ can\\ be\\ selected\\ among\\ the\\ 8\\ most\\ common\\ sequences,\\ according\\ with\\ the\\ ISA\\ 18.1\\ standard\\ ISA\\ A\\ -\\ ISA\\ F1\\ A\\ -\\ ISA\\ F3\\ A\\ -\\ ISA\\ M\\ -\\ ISA\\ M\\ 5\\ -\\ ISA\\ F1\\ M\\ -\\ ISA\\ R\\ 8\\ -\\ ISA\\ F1\\ R8\\  (See\\ table\\ of\\ sequences\\ for\\ more\\ information)\\ The\\ mentioned\\ sequences\\ have\\ following\\ basic\\ sequen­ces:\\ \\ ISA\\ A\\ \\ \\ \\ \\ \\ \\ \\ Alarm\\ signalling\\ with\\ automatic\\ reset,\\ after\\ de­tection.\\ \\ ISA\\ M\\ \\ \\ \\ \\ \\ \\ Alarm\\ signalling\\ with\\ manual\\ reset\\ after\\ detec­tion.\\ \\ ISA\\ R\\ 8\\ Double\\ flashing\\ frequency\\ for\\ alarm\\ signalling\\ (fast\\ for\\ active\\ alarm\\ and\\ slow\\ when\\ coming\\ to\\ normal\\ status)\\ with\\ signalling\\ to\\ the\\ return\\ to\\ normal\\ situation\\ and\\ manual\\ reset.\\ \\ ISA\\ M5\\ Signalling\\ like\\ ISA-M,\\ but\\ without\\ flashing,\\ when\\ optical\\ signalling.\\ \\ ISA\\ F1…“First\\ out”\\ function,\\ to\\ recognise\\ the\\ fi\\ rst\\ tripped\\ alarm,\\ within\\ a\\ group,\\ by\\ means\\ of\\ the\\ optical\\ signal\\ flashing\\ (distinguishing\\ the\\ main\\ alarm\\ from\\ other\\ coupled\\ alarms).\\ The\\ function\\ will\\ be\\ reset\\ after\\ the\\ detection.\\ \\ ISA\\ F3A\\ A\\ particular\\ “fi\\ rst\\ out”\\ function,\\ allowing\\ the\\ dis­tinction\\ of\\ the\\ first\\ alarm\\ \\ from\\ those\\ “coupled\\ alarms”\\ and\\ possible\\ previous\\ alarms\\ already\\ acknowledged.\\ \\ \\ 版权所有\\ 杭州嘉瑞电气有限公司\\ 如有关于本站点的问题或建议,请发邮件至杭州嘉瑞电气有限公司\\ vti_charset:SR|gb2312