vti_encoding:SR|utf8-nl vti_author:SR|JRE505-BF058AD8\\JRE505 vti_modifiedby:SR|USER-AVGPHKC51E\\Administrator vti_timelastmodified:TR|21 Mar 2013 00:56:31 -0000 vti_timecreated:TR|23 May 2008 04:25:37 -0000 vti_title:SR|COMPALARM-AP vti_extenderversion:SR|12.0.0.0 vti_timelastindexed:TW|21 Mar 2013 00:56:31 -0000 vti_backlinkinfo:VX|cpxx.files/sheet001.htm cpxx.htm vti_nexttolasttimemodified:TW|10 Jun 2008 08:16:27 -0000 vti_thicketdir:SW|COMPALARM-AP.files vti_cacheddtm:TX|21 Mar 2013 00:56:31 -0000 vti_filesize:IR|17291 vti_cachedtitle:SR|COMPALARM-AP vti_cachedbodystyle:SR| vti_cachedlinkinfo:VX|H|COMPALARM-AP.files/filelist.xml S|images/bjtp/dbj.gif S|images/bjtp/btbj.gif S|menu.js S|images/bjtp/wzbj.gif S|images/bjtp/wzbj.gif H|cpxx.htm H|cpxx.htm H|cpxx.htm S|images/bjtp/wzbj.gif S|images/bjtp/wzbj.gif S|images/bjtp/wzbj.gif X|COMPALARM-AP.files/image001.jpg S|COMPALARM-AP.files/image002.jpg S|images/bjtp/wzbj.gif S|images/bjtp/wzbj.gif H|mailto:info@jre.com.cn H|http://www.jre.com.cn H|http://www.cnjre.cn vti_cachedsvcrellinks:VX|FHUS|COMPALARM-AP.files/filelist.xml FSUS|images/bjtp/dbj.gif FSUS|images/bjtp/btbj.gif NSUS|menu.js FSUS|images/bjtp/wzbj.gif FSUS|images/bjtp/wzbj.gif FHUS|cpxx.htm FHUS|cpxx.htm FHUS|cpxx.htm FSUS|images/bjtp/wzbj.gif FSUS|images/bjtp/wzbj.gif FSUS|images/bjtp/wzbj.gif FXUS|COMPALARM-AP.files/image001.jpg FSUS|COMPALARM-AP.files/image002.jpg FSUS|images/bjtp/wzbj.gif FSUS|images/bjtp/wzbj.gif NHUS|mailto:info@jre.com.cn NHHS|http://www.jre.com.cn NHHS|http://www.cnjre.cn vti_cachedneedsrewrite:BR|false vti_cachedhasbots:BR|false vti_cachedhastheme:BR|false vti_cachedhasborder:BR|false vti_metatags:VR|HTTP-EQUIV=Content-Type text/html;\\ charset=gb2312 keywords COMPALARM-AP description COMPALARM-AP\\ \\ \\ \\ GENERAL\\ \\ The\\ COMPALARM\\ AP\\ is\\ a\\ point\\ alarm\\ system,\\ with\\ as\\ many\\ normally\\ closed\\ in­put\\ contacts.\\ It\\ givesthe\\ possibility\\ of\\ selecting\\ the\\ alarm\\ sequence\\ according\\ with\\ 30\\ x\\ 30\\ mm\\ cells,\\ fitted\\ with\\ ultra\\ bright\\ white\\ LED’s,\\ \\ achieving\\ a\\ low\\ power\\ consumption\\ and\\ a\\ lamp\\ maintenance\\ free\\ operation.\\ The\\ interconnecting\\ possibility\\ allows\\ to\\ design\\ other\\ supervision\\ alarm\\ systems\\ with\\ many\\ extensions.\\ The\\ alarm\\ systems\\ type\\ COMPALARM\\ AP\\ has\\ been\\ conceived\\ with\\ its\\ very\\ reduced\\ dimensions,\\ but\\ maintaining\\ the\\ characteristics\\ of\\ the\\ COMPALARM\\ A\\ system.\\ This\\ system\\ has\\ been\\ studied\\ for\\ the\\ most\\ critical\\ uses,\\ i.e.\\ electrical\\ plants\\ in\\ which\\ a\\ malfunctioning\\ of\\ a\\ single\\ component\\ should\\ only\\ harm\\ the\\ function\\ of\\ one\\ channel\\ at\\ most.\\ Each\\ channel\\ is\\ protected\\ by\\ optoisolators,\\ which\\ keep\\ free\\ of\\ any\\ external\\ disturbances.\\ Every\\ channel\\ is\\ fitted\\ with\\ a\\ micro-switch\\ allowing\\ the\\ selection\\ of\\ a\\ normally\\ open\\ (N.O.)\\ or\\ a\\ normally\\ closed\\ (N.C.)\\ contact.\\ The\\ COMPALARM\\ AP\\ allows\\ also\\ the\\ selection\\ of\\ two\\ types\\ of\\ sequences\\ by\\ means\\ of\\ a\\ micro-switch,\\ either\\ ISA1\\ (ISA\\ A)\\ or\\ ISA2C\\ (ISA\\ M)\\ and\\ for\\ both\\ sequences\\ the\\ first-out\\ function\\ (F1A\\ and\\ F1M),\\ channel\\ per\\ channel.\\ It\\ is\\ also\\ possible\\ to\\ select\\ a\\ different\\ functioning\\ of\\ the\\ output\\ relays\\ for\\ the\\ acousting\\ signalling\\ in\\ order\\ to\\ have\\ 2\\ signalling\\ types\\ according\\ with\\ the\\ alarm\\ type.\\ With\\ regard\\ to\\ this\\ possibility,\\ there\\ might\\ be\\ the\\ following\\ options,\\ which\\ might\\ be\\ selected\\ by\\ a\\ micro-switch:\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ 6\\ inputs\\ on\\ relay\\ 1\\ and\\ 6\\ inputs\\ on\\ relay\\ 2\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ 8\\ inputs\\ on\\ relay\\ 1\\ and\\ 4\\ inputs\\ on\\ relay\\ 2\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ 10\\ inputs\\ on\\ relay\\ 1\\ and\\ 2\\ inputs\\ on\\ relay\\ 2\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ 12\\ inputs\\ on\\ relay\\ 1\\ and\\ the\\ relay\\ 2\\ working\\ as\\ cumulative\\ for\\ indication\\ of\\ a\\ group\\ in\\ alarm\\ situation\\ \\  \\ The\\ visualisation\\ is\\ being\\ made\\ by\\ special\\ LED’s\\ granting\\ a\\ high\\ brightness\\ together\\ with\\ a\\ long\\ lasting\\ life\\ (millions\\ of\\ working\\ hours),\\ which\\ saves\\ the\\ lamps\\ replacement\\ problems.\\ \\ Features:\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ 12\\ contact\\ inputs\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ 4\\ push\\ button\\ inputs\\ (test,\\ horn\\ off,\\ ack,\\ reset)\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Optoisolated\\ inputs\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Normally\\ open\\ /\\ closed\\ input\\ contacts\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Horn\\ output\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Alarm\\ comulative\\ output\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Flush\\ panel\\ mounting\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ 1\\ wire\\ expansion\\ line\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Low\\ power\\ consumption\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ No\\ lamp\\ maintenance\\ required\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ Fauto-reset\\ power\\ supply\\ fuse\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ 4\\ pre-selectable\\ sequences:\\ ISA\\ A\\ -ISAM\\ -ISAF1A\\ -ISAF1M\\ \\ \\ 版权所有\\ 杭州嘉瑞电气有限公司\\ 如有关于本站点的问题或建议,请发邮件至杭州嘉瑞电气有限公司\\ vti_charset:SR|gb2312